Description
-
Masimo Pulse Oximeter Rad 8
-
Power Cable
The Rad-8 uses Masimo SET pulse oximetry to provide accurate readings even during patient movement or in low-perfusion situations, and to reduce false alarms by up to 95%.
This unit features a large, easy to read color display and a simple to use interface for quick setup and alarm management. The compact and lightweight design is perfect for acute and alternative care settings such as long-term care facilities, homecare, and sleep labs.
Features and Benefits
- Sleep mode with 2 second averaging for bedside studies.
- Home mode for safe and accurate in-home monitoring and trending.
- RadNet and RadLink Interface capability for multi-patient remote monitoring.
- Perfusion Index (PI) indicates arterial pulse signal strength and may be used as a diagnostic tool during low prefusion.
- Low Signal IQ (SIQ) indicator highlights conditions of low signal quality.
- FastSat technology tracks rapid changes in arterial O2 with high fidelity unlike any other pulse oximeter.
- Nurse call interface.
- 72 hours of trending memory.
- Up to 7 hours of internal battery life when fully charged.
- Compatible with Philips Vuelink device interface module.
- APOD (Adaptive Probe Off Detection) provides the best off probe detection of Masimo’s 3 sensitivity modes (ADOP, Normal, and MAX sensitivity).
- Adjustable averaging from 2 – 16 seconds.
- Audible and visual alarms for SpO2, PR, sensor condition, system failure, and low battery.
- Comes in horizontal configuration.
Performance
- Measurement Range
- SpO2: 1-100 %
- Pulse Rate: 25 – 240 (bpm)
- Perfusion Index: 0.02% – 20%
Saturation Accuracy
-
- Saturation: 60% to 80%
- No Motion
- Adults, Infants, Pediatrics: ± 4 digits
- Saturation: 70% to 100%
- No Motion
- Adults, Pediatrics: ± 2 digits
- Neonate: ± 3 digits
- Motion
- Adults, Pediatrics: ±3 digits
- Neonate: ±3 digits
- Low Perfusion
- Adults, Pediatrics: ± 2 digits
- Neonate: ± 3 digits
Pulse Rate Accuracy
- Pulse Rate: 25 – 240 bpm
- No Motion
- Adults, Pediatrics, Neonate: ± 3 digits
- Motion
- Adults, Pediatrics, Neonate: ± 5 digits
- Low Perfusion
- Adults, Pediatrics, Neonate: ± 3 digits
Resolution
- Saturation (%SpO2): 1%
- Pulse Rate (bpm): 1 bpm
Electrical
- AC Power requirements: 100-240 VAC, 47-63 Hz
- Power consumption: 20 VA Max
Batteries
- Handheld
- Type: Sealed lead acid
- Capacity: Up to 7 hours
- Charging Time: 8 Hours
Environmental
- Operating Temperature: 41°F to 104°F (5°C to 40°C)
- Storage Temperature: -40°F to 158°F (-40°C to 70°C)
- Operating Humidity: 5% to 95%, non-condensing
- Operating Altitude:
- 500 mbar to 1060 mbar pressure
- -1000 ft to 18,000 ft (-304 m to 5,486 m)
Physical Characteristics
- Dimensions
- 8.2” x 6” x 3”
- Weight: 2.1 lbs
Modes
- Averaging Mode: 2, 4, 8,10, 12, 14 or 16 seconds
- Sensitivity: APOD, Normal and Max
Alarms
- Audible and visual alarms for high and low saturation (1% to 100%), pulse rate (25 – 240 bpm), sensor condition, system failure and low battery
- Alarm volume
- High: 85dB (min)
- Low: 45dB (min)
Display/Indicators
- Data Display:
- % SpO2
- Alarm Status
- Alarm Silenced Status
- AC Power
- Signal IQ/Pleth Bar
- Perfusion Index Bar
- Battery Status
- No Sensor
- Sensor Off
- Display Type: LED
Reviews